ABC Cable
At Annapurna Rathi Cable Industries Limited, we understand that Nepal’s geography and growing urban density demand smarter electrical solutions. Rathi ABC (Aerial Bunched Cables) represent a shift from traditional bare wires to a secure, insulated system designed for the future of the Nepalese grid.
Manufactured in our state-of-the-art facility in Biratnagar, our ABC conductors are engineered to deliver electricity with maximum safety and minimum loss, regardless of the terrain.
Core Features of Rathi ABC Conductors
- Superior XLPE Insulation: Our conductors are bundled with high-grade Cross-Linked Polyethylene (XLPE) insulation, offering excellent resistance to UV radiation, moisture, and extreme temperature fluctuations common in Nepal.
- High-Strength Messenger Wire: Equipped with a robust aluminum alloy messenger wire that supports the mechanical load, ensuring minimal sagging and high durability against heavy snow or monsoon winds.
- Anti-Theft & Anti-Tamper Design: The bundled, insulated configuration makes illegal tapping significantly more difficult compared to bare wires, directly addressing the challenge of non-technical losses in the distribution network.
- Reduced Fault Rates: By eliminating phase-to-phase short circuits caused by swaying lines or falling tree branches, Rathi ABC ensures a consistent power supply with drastically lower maintenance requirements.
Key Applications in the Nepalese Context
| Application | Why Rathi ABC? |
|---|---|
| Urban Distribution | Ideal for narrow gallis and congested cities where safety clearances for bare wires are impossible to maintain. |
| Rural Electrification | Simplifies installation in hilly regions; can be strung through forested areas with minimal tree trimming. |
| Industrial Zones | Provides stable voltage regulation and high current-carrying capacity for Nepal’s growing manufacturing hubs. |
Technical Specifications
Standard Applicable: IS: 14255: 1995, IS:8130:1984, IS: 7098-1:1998
| S.No. | Description | Unit | Offered | ||||||
|---|---|---|---|---|---|---|---|---|---|
| 4Cx16 Sq.mm | 4Cx25 Sq.mm | 4Cx35 Sq.mm | 4Cx50 Sq.mm | 4Cx70 Sq.mm | 4Cx95 Sq.mm | 4Cx120 Sq.mm | |||
| 1 | Conductor | ||||||||
| No Of Core | No | 4 | 4 | 4 | 4 | 4 | 4 | 4 | |
| Nominal Cross Section Area | mm² | 16 | 25 | 35 | 50 | 70 | 95 | 120 | |
| No. of strand | mm | 7 | 7 | 7 | 7 | 7 | 19 | 19 | |
| Conductor Resistance @ 20 deg. C | Ω/km | Max. 1.91 | Max. 1.2 | Max. 0.868 | Max. 0.641 | Max. 0.443 | Max. 0.32 | Max. 0.253 | |
| 2 | Test on XLPE Insulation | ||||||||
| Thickness (Min.) | mm | 1.2 | 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.7 | |
| Elongation (Min.) | % | Min. 200 | Min. 200 | Min. 200 | Min. 200 | Min. 200 | Min. 200 | Min. 200 | |
| Tensile Strength | N/mm² | Min. 12.5 | Min. 12.5 | Min. 12.5 | Min. 12.5 | Min. 12.5 | Min. 12.5 | Min. 12.5 | |
| Hot set Test | |||||||||
| a. Hot Elongation | % | Max. 175 | Max. 175 | Max. 175 | Max. 175 | Max. 175 | Max. 175 | Max. 175 | |
| b. Permanent Set Elongation | % | Max. 15 | Max. 15 | Max. 15 | Max. 15 | Max. 15 | Max. 15 | Max. 15 | |
| 3 | Volume Resistivity Test @ 27 deg. C | Ohm-cm | Min. 1x1014 | Min. 1x1014 | Min. 1x1014 | Min. 1x1014 | Min. 1x1014 | Min. 1x1014 | Min. 1x1014 |
| 4 | High Voltage Test @ 3kV ac (rms) for 5 minutes | No Fault | |||||||