ABC Cable

At Annapurna Rathi Cable Industries Limited, we understand that Nepal’s geography and growing urban density demand smarter electrical solutions. Rathi ABC (Aerial Bunched Cables) represent a shift from traditional bare wires to a secure, insulated system designed for the future of the Nepalese grid.

Manufactured in our state-of-the-art facility in Biratnagar, our ABC conductors are engineered to deliver electricity with maximum safety and minimum loss, regardless of the terrain.

Core Features of Rathi ABC Conductors

  • Superior XLPE Insulation: Our conductors are bundled with high-grade Cross-Linked Polyethylene (XLPE) insulation, offering excellent resistance to UV radiation, moisture, and extreme temperature fluctuations common in Nepal.
  • High-Strength Messenger Wire: Equipped with a robust aluminum alloy messenger wire that supports the mechanical load, ensuring minimal sagging and high durability against heavy snow or monsoon winds.
  • Anti-Theft & Anti-Tamper Design: The bundled, insulated configuration makes illegal tapping significantly more difficult compared to bare wires, directly addressing the challenge of non-technical losses in the distribution network.
  • Reduced Fault Rates: By eliminating phase-to-phase short circuits caused by swaying lines or falling tree branches, Rathi ABC ensures a consistent power supply with drastically lower maintenance requirements.

Key Applications in the Nepalese Context

ApplicationWhy Rathi ABC?
Urban DistributionIdeal for narrow gallis and congested cities where safety clearances for bare wires are impossible to maintain.
Rural ElectrificationSimplifies installation in hilly regions; can be strung through forested areas with minimal tree trimming.
Industrial ZonesProvides stable voltage regulation and high current-carrying capacity for Nepal’s growing manufacturing hubs.

 

Technical Specifications

Standard Applicable: IS: 14255: 1995, IS:8130:1984, IS: 7098-1:1998

S.No.DescriptionUnitOffered
4Cx16 Sq.mm4Cx25 Sq.mm4Cx35 Sq.mm4Cx50 Sq.mm4Cx70 Sq.mm4Cx95 Sq.mm4Cx120 Sq.mm
1Conductor
No Of CoreNo4444444
Nominal Cross Section Areamm²162535507095120
No. of strandmm777771919
Conductor Resistance @ 20 deg. CΩ/kmMax. 1.91Max. 1.2Max. 0.868Max. 0.641Max. 0.443Max. 0.32Max. 0.253
2Test on XLPE Insulation
Thickness (Min.)mm1.21.21.21.51.51.51.7
Elongation (Min.)%Min. 200Min. 200Min. 200Min. 200Min. 200Min. 200Min. 200
Tensile StrengthN/mm²Min. 12.5Min. 12.5Min. 12.5Min. 12.5Min. 12.5Min. 12.5Min. 12.5
Hot set Test
a. Hot Elongation%Max. 175Max. 175Max. 175Max. 175Max. 175Max. 175Max. 175
b. Permanent Set Elongation%Max. 15Max. 15Max. 15Max. 15Max. 15Max. 15Max. 15
3Volume Resistivity Test @ 27 deg. COhm-cmMin. 1x1014Min. 1x1014Min. 1x1014Min. 1x1014Min. 1x1014Min. 1x1014Min. 1x1014
4High Voltage Test @ 3kV ac (rms) for 5 minutesNo Fault